DETERMINATION OF THE X-RAY IMAGE PARAMETERS IN IRRADIATING STEEL WITHPULSED X-RAY SYSTEMS OF MIRA-2D TYPE

Citation
Yv. Gromov et Yv. Gorbatov, DETERMINATION OF THE X-RAY IMAGE PARAMETERS IN IRRADIATING STEEL WITHPULSED X-RAY SYSTEMS OF MIRA-2D TYPE, The Soviet journal of nondestructive testing, 27(6), 1991, pp. 420-426
Citations number
9
Categorie Soggetti
Material Science
ISSN journal
00385492
Volume
27
Issue
6
Year of publication
1991
Pages
420 - 426
Database
ISI
SICI code
0038-5492(1991)27:6<420:DOTXIP>2.0.ZU;2-M
Abstract
Experiments were carried out to determine the attenuation coefficients of wide and narrow beams of radiation of MIRA-2D pulsed x-ray equipme nt in a steel up to 20 mm thick. The results made it possible to calcu late the parameters of x-ray images in irradiating welded joints.