EFFECT OF PLASMA POLYMER DEPOSITION METHODS ON COPPER CORROSION PROTECTION
Citation
Y. Lin et H. Yasuda, EFFECT OF PLASMA POLYMER DEPOSITION METHODS ON COPPER CORROSION PROTECTION, Journal of applied polymer science, 60(4), 1996, pp. 543-555
Categorie Soggetti
Polymer Sciences
SICI code
0021-8995(1996)60:4<543:EOPPDM>2.0.ZU;2-3
Abstract
The behavior of plasma polymer coating for Cu corrosion protection was
investigated in de cathodic polymerization, with and without anode ma
gnetron enhancement, af magnetron glow discharge polymerization, and r
f glow discharge polymerization. The combination of visual and scannin
g electron microscopy observations established general trends in an ac
celerated wet/dry cycle corrosion testing environment containing 0.1N
chloride ions. Dc anodic magnetron cathodic polymerization of TMS offe
red the best Cu corrosion protection due to an enhanced deposition uni
formity and adhesion of the deposited plasma polymer to the Cu substra
te. No corrosion was observed after 25 wet/dry cycle accelerated corro
sion tests when uncoated Cu suffered a severely generalized attack in
one cycle. Superior corrosion protection was also performed by an af p
lasma polymerized coating of C4F10 + H-2 (1 : 1) at a low-energy input
density and of methane at high-energy input and high deposition thick
ness carried out in the range of this study. The application of plasma
polymers which showed high water vapor permeation resistance and surf
ace dynamic stability greatly reduced the pitting densities. (C) 1996
John Wiley & Sons, Inc.