INCREASING THE WORK SPEED OF RADIOGRAPHERS - THE EFFECT ON THE ACCURACY OF A SET-UP OF A COMPLEX-SHAPED CRANIAL FIELD, PART OF A MATCHED CRANIO SPINAL JUNCTION

Citation
H. Probst et S. Griffiths, INCREASING THE WORK SPEED OF RADIOGRAPHERS - THE EFFECT ON THE ACCURACY OF A SET-UP OF A COMPLEX-SHAPED CRANIAL FIELD, PART OF A MATCHED CRANIO SPINAL JUNCTION, Radiotherapy and oncology, 38(3), 1996, pp. 241-245
Citations number
18
Categorie Soggetti
Oncology,"Radiology,Nuclear Medicine & Medical Imaging
Journal title
ISSN journal
01678140
Volume
38
Issue
3
Year of publication
1996
Pages
241 - 245
Database
ISI
SICI code
0167-8140(1996)38:3<241:ITWSOR>2.0.ZU;2-Q
Abstract
Simulator port films of 22 set-ups of a complex cranial field position ed by radiographers working either at normal or at increased pace were compared with a control film. Analysis showed that accuracy decreased for set-ups achieved at an increased speed, demonstrating risks to tr eatment outcomes incurred by increasing working speed to meet workload demands.