A. Jacolot et al., STABILITY AND COMPATIBILITY OF 2.5 MG ML METHOTREXATE SOLUTION IN PLASTIC SYRINGES OVER 7 DAYS/, International journal of pharmaceutics, 128(1-2), 1996, pp. 283-286
The physico-chemical stability and the compatibility between a 2.5-mg/
ml methotrexate solution and plastic syringes were studied over a 7 da
y period at +4 and 25 degrees C. During this study, pH was determined
and MTX degradation products were assayed by HPLC. The compatibility s
tudy consisted of the titration of reducing substances, TLC of extract
ed additives, assay of extracted ions by AAS, resistivity measurement,
dynamometric test and UV, visible and IR absorption spectrophotometry
. Stability and compatibility studies showed that 2.5 mg/ml methotrexa
te parenteral solution remained chemically stable in a plastic syringe
over a period of 7 days under the tested conditions.