COMPARISON OF THE COOLING PERFORMANCE OF STAGGERED AND IN-LINE ARRAYSOF ELECTRONIC PACKAGES

Citation
Ra. Wirtz et Dm. Colban, COMPARISON OF THE COOLING PERFORMANCE OF STAGGERED AND IN-LINE ARRAYSOF ELECTRONIC PACKAGES, Journal of electronic packaging, 118(1), 1996, pp. 27-30
Citations number
9
Categorie Soggetti
Engineering, Mechanical","Engineering, Eletrical & Electronic
ISSN journal
10437398
Volume
118
Issue
1
Year of publication
1996
Pages
27 - 30
Database
ISI
SICI code
1043-7398(1996)118:1<27:COTCPO>2.0.ZU;2-D
Abstract
The cooling performance of in-fine and staggered regular arrays of sim ulated electronic packages is compared for both sparse and dense packa ging configurations. At equal flow rates, staggered arrays exhibit hig her element heat transfer coefficients and friction factors than in-fi ne arrays. Furthermore, an increase in the packaging density of the el ements results in a moderate reduction in the friction factor with neg ligible change in the heat transfer coefficient. However, when perform ance is expressed in terms of heat transfer rate per unit packaging sy stem volume, dense arrays are found to out perform sparse arrays at eq ual flow rate, applied pressure gradient or pumping power. Furthermore , no significant difference in performance is observed between stagger ed and in-fine configurations when they are compared on the basis of e ither equal coolant flow pressure drop or pumping power.