R8 SVP-MEOH EFFICIENCY MEASUREMENT - AN ACCURATE MEASUREMENT IS REPORTED/

Citation
M. Fredette et M. Costa, R8 SVP-MEOH EFFICIENCY MEASUREMENT - AN ACCURATE MEASUREMENT IS REPORTED/, Pulp & paper Canada, 97(3), 1996, pp. 68-71
Citations number
3
Categorie Soggetti
Materials Science, Paper & Wood
Journal title
ISSN journal
03164004
Volume
97
Issue
3
Year of publication
1996
Pages
68 - 71
Database
ISI
SICI code
0316-4004(1996)97:3<68:RSEM-A>2.0.ZU;2-1
Abstract
The currently accepted method for Cl-2 analysis in ClO2 solution, CPPA J14P, has been found to have small interferences, of the order of +/- 0.05 g/L. When trying to accurately gauge the efficiency of an R8 or SVP-MeOH* at Cl-2 levels of 0.15 to 0.05 g/L, this +/- 0.05 g/L repr esents a relative error of between 33 and 100%. This can lead to an ef ficiency error of between 2 and 4%. The nature of the interferences is described, and then an accurate method to determine Cl-2, useable at the mill site, is presented.