PERFORMANCE OF AN ELECTROMAGNETIC LIQUID KRYPTON CALORIMETER BASED ONA RIBBON ELECTRODE TOWER STRUCTURE
Citation
Gd. Barr et al., PERFORMANCE OF AN ELECTROMAGNETIC LIQUID KRYPTON CALORIMETER BASED ONA RIBBON ELECTRODE TOWER STRUCTURE, Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 370(2-3), 1996, pp. 413-424
Categorie Soggetti
Nuclear Sciences & Tecnology","Physics, Particles & Fields","Instument & Instrumentation",Spectroscopy
SICI code
0168-9002(1996)370:2-3<413:POAELK>2.0.ZU;2-A
Abstract
The NA48 collaboration is preparing a new experiment at CERN aiming to
study CP violation in the K-0-(K-0) over bar system with an accuracy
of 2 x 10(-4) in the parameter Re(epsilon'/epsilon). Decays in two pi(
0)'s will be recorded by a quasi-homogeneous liquid krypton calorimete
r. A liquid krypton calorimeter has been chosen to combine good energy
, position and time resolution with precise charge calibration and lon
g-term stability. The prototype calorimeter incorporating the final de
sign of the electrode read-out structure is presented in this paper. A
n energy resolution of similar or equal to 3.5%/root E with a constant
term smaller than 0.5% has been obtained. The time resolution was fou
nd to be better than 300 ps above 15 GeV.