CONTAMINANT DETERMINATION IN COLD-ROLLING OIL USING HPSEC WITH RI ANDPDA DETECTION

Authors
Citation
Cb. Huang, CONTAMINANT DETERMINATION IN COLD-ROLLING OIL USING HPSEC WITH RI ANDPDA DETECTION, Journal of liquid chromatography & related technologies, 19(6), 1996, pp. 867-888
Citations number
9
Categorie Soggetti
Chemistry Analytical","Biochemical Research Methods
ISSN journal
10826076
Volume
19
Issue
6
Year of publication
1996
Pages
867 - 888
Database
ISI
SICI code
1082-6076(1996)19:6<867:CDICOU>2.0.ZU;2-D
Abstract
A size exclusion liquid chromography (HPSEC) method using refractive i ndex (RT) and photodiode array (PDA) detectors and a BASIC calculation program was developed for high molecular weight contaminant determina tion in the C-15 linear paraffin-based cold rolling oil. Eight laborat ory standards were analyzed to determine the new HPSEC/RI calibration factor for the C-15 linear paraffin rolling oil. Three contaminants an d thirteen standard solutions were evaluated to establish calibration curves. The HPSEC/RI/PDA method will quantitatively determine the conc entrations of polyisobutylene-based hydrodynamic backup bearing lubric ant, mist-applied extreme pressure gear oil for the workroll bearing a nd antiwear hydraulic oil in the cold rolling oil. Deviations for back up bearing lubricant, workroll bearing lubricant and hydraulic oil are approximately 3%, 4% and 7% of the contaminant concentration, respect ively. The BASIC calculation program can assist operators in reducing calculation error and improving speed and accuracy for the HPSEC metho d.