Kk. Chee et al., OPTIMIZATION OF SAMPLE PREPARATION TECHNIQUES FOR THE DETERMINATION OF 4-NONYLPHENOL IN WATER AND SEDIMENT, Journal of liquid chromatography & related technologies, 19(2), 1996, pp. 259-275
Citations number
30
Categorie Soggetti
Chemistry Analytical","Biochemical Research Methods
Sample preparation techniques for the determination of 4-nonylphenol i
n water and sediments were optimized using two-level orthogonal array
design (OAD). Comparison between the use of cartridge-based solid-phas
e extraction and membranous disk-based extraction was made for water s
amples. For sediment samples, microwave-assisted solvent extraction (M
ASE) was employed. A comparison between MASE and classical soxhlet ext
raction of spiked samples was also carried out. 4-Nonylphenol was dete
rmined using high performance liquid chromatography (HPLC) coupled to
both ultraviolet and fluorescence detection.