Tm. Deswiet et Pp. Mitra, POSSIBLE SYSTEMATIC-ERRORS IN SINGLE-SHOT MEASUREMENTS OF THE TRACE OF THE DIFFUSION TENSOR, Journal of magnetic resonance. Series B, 111(1), 1996, pp. 15-22
There have been recent proposals of diffusion-weighting pulse sequence
s that purport to measure the trace of the diffusion tensor, or to wei
ght an image by that rotationally invariant quantity. Here the effect
of a time-dependent diffusion tensor on such sequences is investigated
theoretically. It is found that the time dependence of the diffusion
tensor both breaks the rotational invariance of the pulse sequence and
affects the overall magnitude of the diffusion weighting. These devia
tions are calculated for two pulse sequences, with parameters relevant
to experiments on brain tissue. The departure from rotational invaria
nce is found to be surprisingly small: <1%, for reasonable parameters
and similar to 5% for the most extreme choice of parameters. The overa
ll magnitude of the diffusion weighting, however, may be significantly
altered; 10% is estimated for reasonable parameters. It is proposed t
hat this effect should prove a sensitive probe of time dependence in t
he diffusion tensor. (C) 1996 Academic Press, Inc.