Z. Kong et al., ONLINE STBOD MEASUREMENT AND TOXICITY CONTROL OF WASTEWATERS WITH A RESPIROGRAPHIC BIOSENSOR, Environmental technology, 17(4), 1996, pp. 399-406
This paper presents the results of the implementation of an on-line re
spirographic biosensor- RODTOX - for both BOD monitoring and toxicity
control of incoming wastewater towards a full scale activated sludge t
reatment plant. The results showed that this on-line respirometer prov
ided reliable BOD measurements. At two occasions the apparatus detecte
d incoming toxicity and concomitant with these alarms a deterioration
of the plant performance effectively occurred. Its reliability for tox
icity detection has further been checked by deliberate intoxication ex
periments with creoline. The results showed that the RODTOX gave toxic
ity alarm in time so that preventive measures (interruption of the ent
rance of toxic wastewater) could be taken.