Eg. Myers et al., OPERATION OF A RADIOFREQUENCY ION-SOURCE IN A TANDEM ELECTROSTATIC ACCELERATOR, Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 372(1-2), 1996, pp. 280-282
A radio-frequency ion source using electrostatic inflection has been o
perated in the terminal of a model FN tandem Van de Graaff accelerator
. This arrangement is useful for high resolution resonance experiments
in atomic and low energy nuclear physics and for hydrogen profiling u
sing the the 6.4 MeV H-1(N-15,alpha gamma)C-12 reaction.