DETERMINATION OF PRODUCTS COMPOSITION OF REACTION OF UREA AND DIETHYLENE GLYCOL BY RP HPLC

Citation
W. Miszkiewicz et al., DETERMINATION OF PRODUCTS COMPOSITION OF REACTION OF UREA AND DIETHYLENE GLYCOL BY RP HPLC, Przemysl Chemiczny, 75(4), 1996, pp. 139
Citations number
3
Categorie Soggetti
Engineering, Chemical",Chemistry
Journal title
ISSN journal
00332496
Volume
75
Issue
4
Year of publication
1996
Database
ISI
SICI code
0033-2496(1996)75:4<139:DOPCOR>2.0.ZU;2-P
Abstract
A fast method of separation and quantitative analysis of the mixture o f urea, diethylene glycol, and mono- and dicarbamates of diethylene gl ycol was developed. Post-reaction samples were analyzed directly on th e Hypersil ODS column with RI detector (at 30 degrees C) and water as mobile phase. The procedure is fast, simple, reproducible and appropri ate for routine analyses.