M. Zamani et E. Savvidis, A REAL-TIME PERSONAL NEUTRON DOSIMETER BASED ON PIPS DIODES AND A DOUBLE-LAYER NEUTRON CONVERTER, Radiation protection dosimetry, 63(4), 1996, pp. 299-303
Citations number
14
Categorie Soggetti
Radiology,Nuclear Medicine & Medical Imaging","Nuclear Sciences & Tecnology
A real time personal neutron dosemeter was developed on the basis of a
PIPS diode with a CR-39-(LiF)-Li-6 converter. The detected particles
are protons from neutron scattering on the CR-39 converter and alpha p
articles as well as tritons from the Li-6(n,alpha)H-3 reaction. Backgr
ound and gamma ray contributions were tested using a second equivalent
PIPS diode without converter. The dosemeter characteristics were stud
ied during irradiations in monoenergetic neutron beams at energies fro
m 73 keV up to 14 MeV. The principal properties of the device such as
the energy and angular response as well as the linearity were investig
ated.