HPLC METHOD FOR THE DETERMINATION OF EDTA IN AN OPHTHALMIC CLEANSER

Citation
G. Tran et al., HPLC METHOD FOR THE DETERMINATION OF EDTA IN AN OPHTHALMIC CLEANSER, Journal of liquid chromatography & related technologies, 19(9), 1996, pp. 1499-1508
Citations number
14
Categorie Soggetti
Chemistry Analytical","Biochemical Research Methods
ISSN journal
10826076
Volume
19
Issue
9
Year of publication
1996
Pages
1499 - 1508
Database
ISI
SICI code
1082-6076(1996)19:9<1499:HMFTDO>2.0.ZU;2-Y
Abstract
A reversed-phase high-performance liquid chromatographic (HPLC) proced ure using ultra-violet (UV) detection for the analysis of edetate diso dium (EDTA) via complexation with iron, in an ophthalmic cleanser, is reported. The method is selective, accurate, and reproducible. The pea k area versus EDTA concentration is linear over the range of 50-150% o f its label claim of 0.30 mg/mL, with a detection limit of 200 ng/mL. The mean absolute recovery of EDTA, using the described method, is 102 .7 +/- 0.4% (mean +/- SD, n = 10).