POLYETHYLENE WEAR IN SCANHIP(R) ARTHROPLASTY WITH A 22 OR 32 MM HEAD - 62 MATCHED PATIENTS FOLLOWED FOR 7-9 YEARS

Citation
U. Kesteris et al., POLYETHYLENE WEAR IN SCANHIP(R) ARTHROPLASTY WITH A 22 OR 32 MM HEAD - 62 MATCHED PATIENTS FOLLOWED FOR 7-9 YEARS, Acta orthopaedica Scandinavica, 67(2), 1996, pp. 125-127
Citations number
21
Categorie Soggetti
Orthopedics
ISSN journal
00016470
Volume
67
Issue
2
Year of publication
1996
Pages
125 - 127
Database
ISI
SICI code
0001-6470(1996)67:2<125:PWISAW>2.0.ZU;2-3
Abstract
We measured radiographic polyethylene wear in patients with Scanhip (R ) arthroplasty and no clinical or radiographic signs of loosening. The patients were divided into 2 groups according to head sizes. 32 patie nts (33 hips) had an implant with a 22 mm and 30 patients (34 hips) wi th a 32 mm head. They were followed for 7-9 years. The groups were mat ched for diagnosis, sex, weight, age, and time of follow-up, The mean linear wear with a 22 mm head was 1.1 mm and with a 32 mm head 1.5 mm (p 0.004), which corresponds to a yearly wear rate of 0.15 mm and 0.18 mm, respectively. The mean difference in volumetric wear was greater, 420 mm(3), as compared to 1239 mm(3).