H. Yoshida et al., ON THE STUDY OF MEASUREMENT APPARATUS FOR PARTICLE CONCENTRATION AND ESTIMATION OF PARTICLE-SIZE BY LOG-NORMAL DISTRIBUTION IN GAS-SOLID PIPE-FLOW, Kagaku kogaku ronbunshu, 22(2), 1996, pp. 350-355
Experimental and theoretical studies have been conducted on a method f
or measuring particle concentration and size distribution in gas-solid
pipe four. The measurement can be done continuously and automatically
by the use of anisokinetic sampling. The total mass of the sampled pa
rticles, cyclone and filter box is measured by an electronic mass bala
nce. The mass of the collected particles is proportional to the measur
ement time. In the reduction of experimental data, mass median diamete
r and geometric standard deviation are determined uniquely by the use
of Levin's Equation and the steepest descent mtehod. Particle size dis
tribution obtained in this way agrees well with the conventional impac
tor method.