CALIBRATION OF INDUCTIVE VOLTAGE DIVIDERS AT EXTREMELY LOW-FREQUENCIES

Citation
D. Tarach et G. Trenkler, CALIBRATION OF INDUCTIVE VOLTAGE DIVIDERS AT EXTREMELY LOW-FREQUENCIES, Metrologia, 32(5), 1996, pp. 367-370
Citations number
4
Categorie Soggetti
Physics, Applied","Instument & Instrumentation
Journal title
ISSN journal
00261394
Volume
32
Issue
5
Year of publication
1996
Pages
367 - 370
Database
ISI
SICI code
0026-1394(1996)32:5<367:COIVDA>2.0.ZU;2-4
Abstract
A measuring system based on digital compensators is described. This ca n be used to calibrate inductive voltage dividers (IVDs) at extremely low frequencies. The division error at 1 Hz expressed relative to the complex division factor D at 32 Hz was found to be 1,9 x 10(-5) in mag nitude (uncertainty of measurement u(m) = 1,2 x 10(-6)) and -7,8 x 10( -5) rad in phase (u(p) = 6,5 x 10(-6) rad) for an IVD selected as an e xample. Additional characteristics such as the two-port parameters of the IVD can be measured by adding to the divider reference impedances in order to obtain a six-port network.