Aj. Phillips et al., CONSIDERATION OF CORONA ONSET FROM A WATER DROP AS A FUNCTION OF AIR-PRESSURE, IEE proceedings. Science, measurement and technology, 143(2), 1996, pp. 125-130
The paper identifies three different corona onset mechanisms for a wat
er drop attached to the underside of a conductor as a function of air
pressure, The three different corona onset mechanisms are a result of
two different corona onset processes: water drop instability and ionis
ation of the surrounding air, Both processes are considered in the pap
er, A model which determines the corona onset potential as a function
of air pressure for a water drop attached to a conductor is presented.
The model identifies the three onset mechanisms and accounts for the
previously unexplained transition between the ionisation and instabili
ty modes, The corona onset potential is determined by modelling both t
he stability of the drop and the ionisation of the surrounding air as
a function of the potential applied to the conductor, This is done ove
r a range of air pressures resulting in an 'onset versus air pressure'
curve, The entire model is then verified by experimentation. The mode
l accounts for changes in the drop shape with changes in applied poten
tial and the influence of this on the E-field distribution and hence t
he ionisation processes, Drop volume, conductor surface conditions and
applied E-field divergency are accounted for.