In the course of our studies on variable reflection windows involving
copper deposition, we have proposed to use P(EO)nKCuxI1+x complexes. T
he excess I- ions stabilizes copper (I) through formation of [CuIn+1]n
- and the transport of copper is solely due to the diffusion of anioni
c complexes which acts as copper vehicles. Copper electrodeposition ha
s been observed. The stripping of the copper layers strongly depends u
pon the relaxation time between the copper plating and the beginning o
f the anodic voltametric scan. The copper deposit slowly vanishes with
time. A cathodic current is observed before the copper plating proces
s which we relate to the possible reduction of an oxidizing species pr
esent in the electrolyte. The search for such oxidizing species (Cu2+,
I3-) has been made using ESR and Raman spectroscopy and we have shown
the presence of I3-).