Gz. Xie et Ma. Sheard, COMPARISON OF 2 METHODS USED TO DETERMINE APPARENT HEAT-TRANSFER COEFFICIENT FOR POUCHES PASTEURIZED IN A COMBINATION OVEN, Lebensmittel-Wissenschaft + Technologie, 29(1-2), 1996, pp. 100-105
Apparent heat transfer coefficients between pouch and heating medium i
n a combination oven on Vario-steaming mode were determined by compari
ng the experimental and simulated temperature histories and by the lea
st square and optimization methods. Temperature histories and related
P-70 values from experiments and simulation were compared One stage ap
proximation of the heating process resulted in large mean square-roote
d deviations (MSRDs) in simulated temperature histories, 2.6 +/- 0.4 d
egrees C and 2.8 +/- 0.4 degrees C, and also large errors in predicted
mean P-70, -21.5% and -11.3%, using h values determined by the least
square and optimization methods, respectively. According to heat trans
fer mechanisms the heating process was divided into two stages, i.e. a
ir and mixture of steam and air heating. MSRDs were reduced to 0.6 +/-
0.3 degrees C for both methods and errors in predicted mean P-70 were
reduced to 4.3% and 3.0% for the least square and optimization method
s respectively. The differences in h values, MSRDs and mean P-70 produ
ced by the two methods became negligible. (C) 1996 Academic Press Limi
ted.