C. Kiesner et al., DIFFERENTIATING FEATURES FOR EVALUATING H EAT-TREATMENT OF MILK - ASPECTS CONCERNING EQUIPMENT AND PROCESS ENGINEERING, Kieler Milchwirtschaftliche Forschungsberichte, 48(1), 1996, pp. 49-62
For thermal treatment of milk samples temperature-time combinations in
the range between 62-140 degrees C, as well as equivalent holding tim
es extended up to some minutes were applied. This was possible by use
of a discontinuously operating autoclave and a continuous pilot heatin
g plant equipped with exchangeable holders. In the range studied all l
egally admitted heating processes can be incorporated. An equivalent h
olding time (time of treatment) was calculated by considering the proc
ess-inherent heating up and cooling phases. It comprises, besides the
thermally induced conversion of a chemical reaction at constant temper
ature (heating temperature, process temperature) only during the holdi
ng phase also the conversions during the heating up and cooling phases
. As a basis for calculating the equivalent treatment time the sterili
zation value F-0 was used. For a number of chemical reactions, e.g. re
arrangement of 1-methyladenosine and furosine formation, it has been s
hown that in computing the equivalent holding time the size of the z-v
alue selected is of almost no importance for the determination of the
reaction velocity constants and, hence, also the kinetic parameters (z
-value). The general applicability of this method - also as regards ot
her heat-induced chemical reactions -needs, however, further clarifica
tion.