MEASUREMENT OF THE OZONE CONCENTRATION IN THE LOWER TROPOSPHERE BY A DIFFERENTIAL ABSORPTION LIDAR SYSTEM

Citation
Vs. Bukreev et al., MEASUREMENT OF THE OZONE CONCENTRATION IN THE LOWER TROPOSPHERE BY A DIFFERENTIAL ABSORPTION LIDAR SYSTEM, Kvantovaa elektronika, 23(4), 1996, pp. 363-367
Citations number
11
Categorie Soggetti
Physics, Applied","Engineering, Eletrical & Electronic
Journal title
ISSN journal
03687147
Volume
23
Issue
4
Year of publication
1996
Pages
363 - 367
Database
ISI
SICI code
0368-7147(1996)23:4<363:MOTOCI>2.0.ZU;2-2
Abstract
A description is given of a lidar system based on an excimer KrF laser with hydrogen and deuterium SRS converters, designed for measuring th e daytime and nighttime ozone concentrations at altitudes 0.3-5 km by a differential absorption method. An investigation of the evolution of the concentration of the tropospheric ozone over a period of 24 hours , and also over a longer period, demonstrated that the system can be u sed to monitor regularly the tropospheric ozone and its chemical trans formations.