A comparative study is presented of several models describing steady-s
tate heat flow through an assembly consisting of a primary surface (wa
ll) and attached extended surface (fin). Attention is focused on the v
alidity of four performance indicators. The work shows that the augmen
tation factor is the only indicator capable of correctly predicting th
e behavioral trends of the rate of heat flow through the assembly as t
he influencing physical parameters are varied.