THE DEVELOPMENT OF AN OZONE CONTACT TANK SIMULATION-MODEL

Citation
J. Murrer et al., THE DEVELOPMENT OF AN OZONE CONTACT TANK SIMULATION-MODEL, Ozone: science & engineering, 17(6), 1995, pp. 607-617
Citations number
6
Categorie Soggetti
Environmental Sciences
ISSN journal
01919512
Volume
17
Issue
6
Year of publication
1995
Pages
607 - 617
Database
ISI
SICI code
0191-9512(1995)17:6<607:TDOAOC>2.0.ZU;2-9
Abstract
Anglian Water (AW) operates ozone facilities as a treatment stage at a ll its surface water sources. The main ozone treatment stage takes pla ce after filtration in multi-compartment concrete ozone contactors. Th ese have two stages of ozone gas injection via ceramic bubble diffuser s and two decay stages. To enable AW to gain a better understanding of the contact tank performance, a computer simulation model incorporati ng Computational Fluid Dynamics and ozone process modeling was develop ed in conjunction with AEA Harwell. The model was calibrated using sit e data from Alton WTW. The results were used to improve the tank desig n and to optimize the ozone dose; this resulted in improved performanc e and a significant reduction in ozone dose.