A flow injection configuration is proposed for the determination of Tl
-I and Tl-III individually and for mixtures of both analytes, The meth
od allows speciation and fluorimetric detection of thallium in flowing
solutions. Thallium(I) is determined by measuring its fluorescence in
an HCI medium (lambda(ex) = 227 nm; lambda(em) = 419 nm). The determi
nation of TIIII is based on the rapid reduction of this ion by thioure
a with the concomitant formation of fluorescent TII. The inclusion of
a selection valve in the manifold configuration allows the successive
determination of the two ions, Linear calibration graphs were obtained
between 5.0 x 10(-8) and 1.0 x 10(-5) mol l(-1) of Tl-I and between 1
.0 x 10(-7) and 1.0 x 10(-5) mol l(-1) of Tl-III. The applicability of
the method was demonstrated by investigating the effect of potential
interferents and by the analysis of synthetic samples, The method was
successfully applied to the determination of thallium in soils and zin
c ores.