A TECHNIQUE OF REVISION OF FAILED ACETABULAR COMPONENTS LEAVING THE FEMORAL COMPONENT IN-SITU

Citation
Mj. Neil et Mi. Solomon, A TECHNIQUE OF REVISION OF FAILED ACETABULAR COMPONENTS LEAVING THE FEMORAL COMPONENT IN-SITU, The Journal of arthroplasty, 11(4), 1996, pp. 482-483
Citations number
6
Categorie Soggetti
Engineering, Biomedical
Journal title
ISSN journal
08835403
Volume
11
Issue
4
Year of publication
1996
Pages
482 - 483
Database
ISI
SICI code
0883-5403(1996)11:4<482:ATOROF>2.0.ZU;2-8
Abstract
Management of a failed acetabular prosthesis in the presence of a well -fixed femoral prosthesis poses a technical challenge in revision join t arthroplasty. While failures can occur at any age during the lifetim e of a prosthesis, a pattern has emerged of earlier failure of the fem oral component and later failure of the acetabular component. The auth ors describe a technique in which the stable femoral prosthesis is lef t in situ during acetabular revision. The advantages of this technique include excellent exposure of the acetabulum, reduction in operative time and intraoperative morbidity, as well as early postoperative mobi lization.