DYNAMIC-RESPONSE OF A SERVOVALVE CONTROLLED HYDRAULIC MOTOR DRIVEN CENTRIFUGAL PUMP

Citation
Lj. Xu et al., DYNAMIC-RESPONSE OF A SERVOVALVE CONTROLLED HYDRAULIC MOTOR DRIVEN CENTRIFUGAL PUMP, Journal of dynamic systems, measurement, and control, 118(2), 1996, pp. 253-258
Citations number
13
Categorie Soggetti
Engineering, Mechanical
ISSN journal
00220434
Volume
118
Issue
2
Year of publication
1996
Pages
253 - 258
Database
ISI
SICI code
0022-0434(1996)118:2<253:DOASCH>2.0.ZU;2-7
Abstract
A servovalve controlled hydraulic motor driven centrifugal pump tvas d ynamically modelled using linearized analysis. The expressions for the system gain natural frequency, and damping ratio in terms of componen t physical parameters were derived. An optimization model estimation p rocedure was developed and applied to the step responses of such a sys tem constructed of common commercial components. The experimental syst em had a 4.2 Hz natural frequency and 1.2 damping ratio. The research indicates that the dynamic responses of a servovalve controlled centri fugal pump can be appropriately modelled for applications in industry and agriculture where the output flow rate needs to be dynamically cha nged.