PERFORMANCE OF A COMPTON TELESCOPE USING POSITION-SENSITIVE GERMANIUMDETECTORS

Citation
Bf. Phlips et al., PERFORMANCE OF A COMPTON TELESCOPE USING POSITION-SENSITIVE GERMANIUMDETECTORS, IEEE transactions on nuclear science, 43(3), 1996, pp. 1472-1475
Citations number
6
Categorie Soggetti
Nuclear Sciences & Tecnology","Engineering, Eletrical & Electronic
ISSN journal
00189499
Volume
43
Issue
3
Year of publication
1996
Part
2
Pages
1472 - 1475
Database
ISI
SICI code
0018-9499(1996)43:3<1472:POACTU>2.0.ZU;2-6
Abstract
We describe the use of position sensitive planar germanium detectors i n a Compton telescope/camera. This Compton telescope achieves the very good energy resolution (Delta Etotal < 4 keV) associated with germani um detectors and good position resolution (2 mm. By combining a 25 x 2 5 strip (2 mm pitch) detector with a 5 x 5 strip detector (9 mm pitch) , we created a telescope with 625 x 25 pixel combinations. Using this detector pair, we have reconstructed positions with an angular resolut ion of similar to 1 degree FWHM and 15 arcminute centroiding. Point so urces are identified with less than 100 full energy events with simple image reconstruction. The angular resolution is currently limited by the uncertainty in the absolute position of the detectors and the size of the second detector pixels. We show the expected angular resolutio n when the pixel size no longer dominates the angular resolution and d iscuss proposed applications.