POINT-SOURCE RESOLUTION PERFORMANCE OF A GERMANIUM COMPTON CAMERA

Citation
Ps. Haskins et al., POINT-SOURCE RESOLUTION PERFORMANCE OF A GERMANIUM COMPTON CAMERA, IEEE transactions on nuclear science, 43(3), 1996, pp. 1832-1836
Citations number
9
Categorie Soggetti
Nuclear Sciences & Tecnology","Engineering, Eletrical & Electronic
ISSN journal
00189499
Volume
43
Issue
3
Year of publication
1996
Part
2
Pages
1832 - 1836
Database
ISI
SICI code
0018-9499(1996)43:3<1832:PRPOAG>2.0.ZU;2-F
Abstract
One of the critical performance parameters for a Compton Camera Imager (CCI) is the Point Source Location Accuracy (PSLA). This paper descri bes analysis of both experimental and simulated data to evaluate the p oint source resolving power of a germanium Compton Camera Imager. The experimental data are taken from a set of experiments performed in 199 3 at Naval Research Laboratory[1]. Subsequent design studies have util ized Monte Carlo simulations to predict the performance parameters for a number of detector geometries. Presented in this paper are the resu lts from one of those configurations.