MEASUREMENT OF POSITIVE DISPLACEMENT PUMP FLOW RIPPLE AND IMPEDANCE

Citation
Dn. Johnston et Je. Drew, MEASUREMENT OF POSITIVE DISPLACEMENT PUMP FLOW RIPPLE AND IMPEDANCE, Proceedings of the Institution of Mechanical Engineers. Part I, Journal of systems and control engineering, 210(1), 1996, pp. 65-74
Citations number
17
Categorie Soggetti
Robotics & Automatic Control
ISSN journal
09596518
Volume
210
Issue
1
Year of publication
1996
Pages
65 - 74
Database
ISI
SICI code
0959-6518(1996)210:1<65:MOPDPF>2.0.ZU;2-M
Abstract
The secondary source method forms the British Standard for pump fluid- borne noise testing. This is a powerful technique but requires care in order to produce accurate results. This paper describes practical asp ects for implementing the method. The requirements for the test rig, d ata acquisition system and analysis are detailed. The British Standard specifies that either mathematical modelling or linear interpolation is used on the source impedance measurements. A method for smoothing t he impedance results is described in this paper, which is shown to giv e more repeatable results than linear interpolation. Some physically r ealistic mathematical models of pump impedance are described, and thei r use in determining the internal flow ripple discussed.