ROUND-ROBIN TEST FOR MEASURING POLYCHLORI NATED DIBENZODIOXINS AND DIBENZOFURANS IN WORKPLACE AIR

Citation
N. Lichtenstein et al., ROUND-ROBIN TEST FOR MEASURING POLYCHLORI NATED DIBENZODIOXINS AND DIBENZOFURANS IN WORKPLACE AIR, Gefahrstoffe, Reinhaltung der Luft, 56(6), 1996, pp. 239-245
Citations number
8
Categorie Soggetti
Environmental Sciences","Engineering, Civil","Engineering, Environmental
ISSN journal
09498036
Volume
56
Issue
6
Year of publication
1996
Pages
239 - 245
Database
ISI
SICI code
0949-8036(1996)56:6<239:RTFMPN>2.0.ZU;2-M
Abstract
Six simultaneous samplings were carried out in an aluminium recycling plant to validate a method for determining the concentration of polych lorinated dibenzodioxines and -furans (PCDD/PCDF) in workplace air. Th e sampling device was developed in the ''Berufsgenossenschaftliches In stitut fur Arbeitssicherheit'' (BIA) and is able to sample particulate PCDD/PCDF using a glass fiber filter according to the total dust defi nition and filter-passing PCDD/PCDF using a layer of polyurethane foam . The samples were analysed in six different laboratories, which were allowed to use different analytical methods. The relative standard dev iation for the results is 25%. This satisfies the requirements of DIN EN 482 for the performance of procedures for measuring chemical agents .