Nw. Shammas et al., PERFORATION OF SAPHENOUS-VEIN GRAFT DURING CORONARY STENTING - A CASE-REPORT, Catheterization and cardiovascular diagnosis, 38(3), 1996, pp. 274-276
We report on a case of coronary perforation during stenting of a saphe
nous vein graft with a biliary stent. Sealing of the perforation was a
chieved with another biliary stent deployed within the first stent at
the site of the perforation, and with prolonged balloon inflation. Thi
s case illustrates that vein graft perforation can occur with coronary
stenting, and could potentially be treated with prolonged balloon inf
lation and/or stenting at the site of the first stent. (C) 1996 Wiley-
Liss, Inc.