PERFORATION OF SAPHENOUS-VEIN GRAFT DURING CORONARY STENTING - A CASE-REPORT

Citation
Nw. Shammas et al., PERFORATION OF SAPHENOUS-VEIN GRAFT DURING CORONARY STENTING - A CASE-REPORT, Catheterization and cardiovascular diagnosis, 38(3), 1996, pp. 274-276
Citations number
2
Categorie Soggetti
Cardiac & Cardiovascular System
ISSN journal
00986569
Volume
38
Issue
3
Year of publication
1996
Pages
274 - 276
Database
ISI
SICI code
0098-6569(1996)38:3<274:POSGDC>2.0.ZU;2-S
Abstract
We report on a case of coronary perforation during stenting of a saphe nous vein graft with a biliary stent. Sealing of the perforation was a chieved with another biliary stent deployed within the first stent at the site of the perforation, and with prolonged balloon inflation. Thi s case illustrates that vein graft perforation can occur with coronary stenting, and could potentially be treated with prolonged balloon inf lation and/or stenting at the site of the first stent. (C) 1996 Wiley- Liss, Inc.