PRELIMINARY DESIGN OF A SIMULATED COUNTERCURRENT CHROMATOGRAPHIC SYSTEM FOR THE SEPARATION OF PRAZIQUANTEL ENANTIOMERS

Authors
Citation
Bg. Lim et Cb. Ching, PRELIMINARY DESIGN OF A SIMULATED COUNTERCURRENT CHROMATOGRAPHIC SYSTEM FOR THE SEPARATION OF PRAZIQUANTEL ENANTIOMERS, Journal of chromatography, 734(2), 1996, pp. 247-258
Citations number
22
Categorie Soggetti
Chemistry Analytical","Biochemical Research Methods
Journal title
Volume
734
Issue
2
Year of publication
1996
Pages
247 - 258
Database
ISI
SICI code
Abstract
An empirical design approach for the separation of praziquantel enanti omers using a simulated counter-current (SCC) chromatographic system i s presented. The elution volume of the two components to be separated was determined from batch chromatography and was used to evaluate the flow conditions in each section of the SCC unit. The effects of the fl ow-rate and the number of columns in each section, the throughput and the feed concentration on the extract and raffinate purity of the two streams were studied. This design approach provides sufficient accurac y and an adequate representation of the SCC system. It also provides v aluable insight into the main factors governing the behaviour of the s ystem.