ONLINE MEMBRANE INLET MASS-SPECTROMETRY FOR FEEDBACK-CONTROL OF PRECURSOR CONCENTRATION IN PENICILLIN FERMENTATION

Authors
Citation
Kf. Hansen et H. Degn, ONLINE MEMBRANE INLET MASS-SPECTROMETRY FOR FEEDBACK-CONTROL OF PRECURSOR CONCENTRATION IN PENICILLIN FERMENTATION, Biotechnology techniques, 10(7), 1996, pp. 485-490
Citations number
6
Categorie Soggetti
Biothechnology & Applied Migrobiology
Journal title
ISSN journal
0951208X
Volume
10
Issue
7
Year of publication
1996
Pages
485 - 490
Database
ISI
SICI code
0951-208X(1996)10:7<485:OMIMFF>2.0.ZU;2-5
Abstract
A sampling system which enables on-line measurements of the precursor phenoxyacetic acid (POAA) in penicillin fermentation by membrane inlet mass spectrometry is presented and its capacity for feed-back regulat ion of POAA to a low predefined concentration in a penicillin-V fermen tation over 150 hours is demonstrated. The system measures alternately filtered sample and standard solution in a measuring cycle which is s horter than the response time of membrane inlet mass spectrometry (MIM S) but sufficiently long to decide whether the concentration of POAA i n the sample is higher or lower than in the standard solution at set p oint concentration. The decision is used for on-off regulation of the addition of POAA.