SPECTRAL-LINE SHAPES IN A THERMIONIC DIODE DETECTOR

Citation
Sa. Bhatti et al., SPECTRAL-LINE SHAPES IN A THERMIONIC DIODE DETECTOR, Measurement science & technology, 7(7), 1996, pp. 1038-1041
Citations number
17
Categorie Soggetti
Instument & Instrumentation",Engineering
ISSN journal
09570233
Volume
7
Issue
7
Year of publication
1996
Pages
1038 - 1041
Database
ISI
SICI code
0957-0233(1996)7:7<1038:SSIATD>2.0.ZU;2-J
Abstract
We report spectral line shapes which resemble window resonance profile s or hole-burning profiles of the resonance lines of barium and lithiu m using a thermionic diode detector. It is shown that the observed pec uliar line shapes arise from the reduction in the space-charge potenti al barrier height in the detector when a large number of ions are prod uced in the detector rather than from any atomic parameter.