An updated version of the look-up table for critical heat flux (CHF) h
as been developed jointly by AECL Research (Canada) and IPPE (Obninsk,
Russia). It is based on an extensive data base of CHF values obtained
in tubes with a vertical upward flow of steam-water mixture. While th
e data base covers a wide range of flow conditions, the look-up table
is designed to provide CHF values for 8 mm tubes at discrete values of
pressure, mass flux and dryout quality covering the ranges 0.1 to 20.
0 MPa, 0.0 to 8.0 Mg m(-2) s(-1) and -0.5 to +1.0 respectively. Linear
interpolation is used to determine the CHF for conditions between the
tabulated values, and an empirical correction factor is introduced to
extend this CHF table to tubes of diameter values other than 8 mm. Co
mpared against the combined AECL-IPPE world data bank (consisting of 2
2 946 data points after excluding duplicate data and obviously erroneo
us data), the 1995 look-up table predicts the data with overall averag
e and root-mean-square errors of 0.69% and 7.82% respectively. An asse
ssment of various CHF tables and several empirical correlations shows
that the 1995 table consistently provides the best prediction accuracy
and is applicable to the widest range of conditions.