Z. Khoury et al., EFFECTS OF TRANSDERMAL NICOTINE PATCHES ON AMBULATORY ECG MONITORING FINDINGS - A DOUBLE-BLIND-STUDY IN HEALTHY SMOKERS, Cardiovascular drugs and therapy, 10(2), 1996, pp. 179-184
Citations number
35
Categorie Soggetti
Pharmacology & Pharmacy","Cardiac & Cardiovascular System
The cardiovascular effects and safety of transdermal nicotine patches
were assessed in 50 healthy smokers using repeated 48 hour ambulatory
electrocardiographic monitoring as a part of a smoking cessation progr
am. Following baseline measurements, subjects were randomized to activ
e (n = 25) or placebo (n = 25) treatment groups for a period of 2 week
s. Twenty-two patients in each group completed the trial. During the t
reatment period, subjects also received behavioral supportive therapy.
Heart rate and blood pressure were significantly reduced relative to
baseline both groups. In the active treatment group, mean values at ba
seline and after 2 weeks of double-blind treatments were as follows: h
eart rates, 74.0 and 71.3 beats/min, respectively; systolic blood pres
sure, 108.9 and 106.9 mmHg; and diastolic blood pressure, 69.7 and 68.
2 mmHg, respectively. Values for the placebo group were as follows: he
art rate, 73.2 and 69.6 beats/min; systolic blood pressure, 110.6 and
105.3 mmHg; diastolic blood pressure, 71.4 and 70.5 mmHg. The confiden
ce intervals of the mean for the differences between the groups are as
follows: heart rate, -4.0 +8.2; systolic blood pressure, -6.7, +10.1;
diastolic blood pressure, -7.9, +3.9. There were no changes in the fr
equency of atrial or ventricular arrhythmia as documented by repeated
48 hour ambulatory ECG recordings from baseline period before stopping
smoking compared with the treatment period in the active as well as i
n the placebo groups. No ischemic events were detected in any of the v
olunteers during either the baseline or treatment periods. As a measur
e of smoking abstinence, we assessed the level of carbon monoxide in e
xpired air; in the active group, the mean levels fell from 14.2 to 4.4
ppm after smoking cessation and in the placebo group from 13.2 to 4.2
ppm. The mean urine cotinine level fell from 8.18 mmol/l at baseline
to 5.74 mmol/l after 2 weeks of treatment in the active group and from
8.78 to 3.93 mmol/l in the placebo group. The number of cigarettes sm
oked per week in both treatment groups was significantly reduced: from
175.2 to 8.4 for the active group and from 136 to 8.6 for the placebo
group. Eleven out of 22 subjects in each group quit smoking completel
y. Smoking withdrawal symptoms during the first week of treatment were
more severe in the placebo group than in those on active treatment. T
here were no significant side effects in either the placebo or the act
ive treatment groups. These results indicate that nicotine delivered b
y transdermal system is free of cardiac adverse effects in healthy vol
unteers.