M. Adami et al., POTENTIOMETRIC ALTERNATING BIOSENSING SYSTEM FOR IN CONTINUUM TOXICITY TESTS ON CELL-POPULATION, Journal of biochemical and biophysical methods, 32(3), 1996, pp. 171-181
In this paper, we investigate the possibility to monitor, in continuum
, changes of cellular metabolism. Examples of this feature are shown:
metabolic changes due to drugs administration are evaluated as a decre
ase of extracellular acidification rate on CHO-K1 and HeLa cells. Para
llel experiments with a standard test were performed to validate the r
esults obtained with the biosensor.