Operational characteristics of a fountain effect pump in a HeII flow l
oop have been experimentally investigated. Relations between a Heir ma
ss flow rate in the loop and a supplied heat to the pump were measured
with different dimensions of the porous plug and the tubes which make
up the loop, It is confirmed that the supplied heat can be used effec
tively to drive HeII when appropriate sizes of the plug and the tubes
at the inlet and outlet of the pump are chosen, The tube at the inlet
of the plug is required to remove most of the supplied heat and to sup
press an increase of HeII temperature at the inlet and outlet of the p
lug, The tube at the outlet of the plug is required to restrict the he
at leakage to the downstream of the flow.