PERFORMANCE OF FOUNTAIN EFFECT PUMPS WITH DIFFERENT HEII FLOW LOOPS

Citation
T. Okamura et al., PERFORMANCE OF FOUNTAIN EFFECT PUMPS WITH DIFFERENT HEII FLOW LOOPS, IEEE transactions on magnetics, 32(4), 1996, pp. 2772-2775
Citations number
10
Categorie Soggetti
Engineering, Eletrical & Electronic","Physics, Applied
ISSN journal
00189464
Volume
32
Issue
4
Year of publication
1996
Part
1
Pages
2772 - 2775
Database
ISI
SICI code
0018-9464(1996)32:4<2772:POFEPW>2.0.ZU;2-6
Abstract
Operational characteristics of a fountain effect pump in a HeII flow l oop have been experimentally investigated. Relations between a Heir ma ss flow rate in the loop and a supplied heat to the pump were measured with different dimensions of the porous plug and the tubes which make up the loop, It is confirmed that the supplied heat can be used effec tively to drive HeII when appropriate sizes of the plug and the tubes at the inlet and outlet of the pump are chosen, The tube at the inlet of the plug is required to remove most of the supplied heat and to sup press an increase of HeII temperature at the inlet and outlet of the p lug, The tube at the outlet of the plug is required to restrict the he at leakage to the downstream of the flow.