Quench observation using quench antennas is now being performed routin
ely on RHIC dipole and quadrupole magnets. Recently, a quench antenna
was used on a RHIC IR magnet which is heavily instrumented with voltag
e taps. It was confirmed that the signals detected in the antenna coil
s do not contradict the voltage tap signals. The antenna also detects
a sign of mechanical disturbance which could be related to a training
quench. This paper summarizes signals detected in the antenna and disc
usses possible causes of these signals.