MODIFIED NEEDLE ELEVATION TECHNIQUE FOR MISPLACED NORPLANT(R) IMPLANTS REMOVAL

Citation
S. Taneepanichskul et al., MODIFIED NEEDLE ELEVATION TECHNIQUE FOR MISPLACED NORPLANT(R) IMPLANTS REMOVAL, Contraception, 54(2), 1996, pp. 87-89
Citations number
7
Categorie Soggetti
Obsetric & Gynecology
Journal title
ISSN journal
00107824
Volume
54
Issue
2
Year of publication
1996
Pages
87 - 89
Database
ISI
SICI code
0010-7824(1996)54:2<87:MNETFM>2.0.ZU;2-D
Abstract
This study reports on a simple, feasible and easily learned technique for Norplant(R) implants removal. This technique is modified from the needle elevation technique. The objective of this study was to introdu ce an alternative Norplant implants removal technique, especially for misplaced capsules. Fifteen Norplant implants clients whose capsules w ere difficult to palpate had removal by this technique. The mean durat ion of Norplant implants use was 18.4 +/- 22.5 months. The mean length of removal time was 10.4 +/- 4.5 minutes. None of the capsules was da maged during the removal. No immediate or late complications were obse rved. The conclusion is that the modified needle elevation technique i s a simple and easy method of removing misplaced Norplant capsules wit h less complications.