E. Noel et al., MEASUREMENT OF THE NUCLEAR-POLARIZATION OF OPTICALLY PUMPED HE-3 ATOMS USING A HE-4 MAGNETOMETER, Journal de physique. III, 6(8), 1996, pp. 1127-1132
A He-4 magnetometer is used to detect the static magnetic field produc
ed by optically pumped He-3 nuclei submitted to a RF discharge. The ex
periment is made in a magnetic held whose value (40 mu T) is close to
the earth field value. From this measurement, we determine the He-3 nu
clear polarisation P-n. For comparison, simultaneous determination of
P-n is made by measuring the degree of circular polarisation of one of
the fluorescence lines emitted from the discharge.