Sp. Bhattacharya et al., AN ANALYSIS OF THE ANGULAR SCATTER MEASUREMENT TO DETERMINE THE OPTICAL-CONSTANTS OF COAL AND ASHY MATERIALS, International communications in heat and mass transfer, 23(6), 1996, pp. 809-821
Theoretical analysis has been presented to assess the potential of ang
ular scatter measurements to estimate the optical constants of combust
ion particulates. While the forward intensities are insensitive, the b
ackward intensities are very weak and moderately sensitive to the opti
cal constants only under a limited range of conditions. Thus accuracy
of the optical constants retrieved from angular scatter measurements,
which are complicated to perform, may be low particulary for weakly ab
sorbing combustion particulates.