DETERMINATION OF COMPLEX-MIXTURES OF AIRBORNE ISOCYANATES AND AMINES .2. TOLUENE DIISOCYANATE AND AMINOISOCYANATE AND TOLUENEDIAMINE AFTER THERMAL-DEGRADATION OF A TOLUENE DIISOCYANATE-POLYURETHANE
H. Tinnerberg et al., DETERMINATION OF COMPLEX-MIXTURES OF AIRBORNE ISOCYANATES AND AMINES .2. TOLUENE DIISOCYANATE AND AMINOISOCYANATE AND TOLUENEDIAMINE AFTER THERMAL-DEGRADATION OF A TOLUENE DIISOCYANATE-POLYURETHANE, Analyst, 121(8), 1996, pp. 1101-1106
An LC-MS method is presented for the determination of thermal decompos
ition products of polyurethane, The method is based on the collection
of air samples in midget impinger flasks containing 0.01 mol l(-1) dib
utylamine (DBA) dissolved in toluene, DBA reacts with isocyanates to g
ive urea derivatives, The amines simultaneously collected were derivat
ized with ethyl chloroformate (ET) to give urethane derivatives, Two i
somers of toluene diisocyanate (2,4- and 2,6-TDI), toluene-2,4- and -2
,6-diamine (TDA), three isomers of toluene aminoisocyanates and oligom
ers with two and three aromatic rings were determined in air containin
g thermal decomposition products of TDI-polyurethane. LC with gradient
elution, at 0.5 ml min(-1) starting with acetonitrile-water (46 + 54)
and ending after 14 min with acetonitrile-water (77.5 +/- 22.5) and a
tmospheric pressure ionization monitoring of positive ions demonstrate
d highly sensitive and selective determinations, Quantification was pe
rformed by monitoring the molecular ion [M + 1](+) of TDI-DBA and TDA-
ET derivatives, The instrumental detection limit was 1 nmol l(-1) of T
DI-DBA and 2 nmol l(-1) of TDA-ET. Linear calibration curves were obta
ined and the correlation coefficient was 0.9981-0.9996 for 50-500 nmol
l(-1) (n = 14), The over-all precision for samples spiked at a concen
tration of 500 nmol l(-1) of 2,4- and 2,6-TDA-ET and 2,4- and 2,6-TDI-
DBA was 1.7, 1.6, 1.8 and 1.9% (n = 11), respectively.