J. Sato et al., MEASUREMENT OF INSULIN CONTENT AT DIFFERENT SITES OF AN INSULIN PREPARATION VIAL, Current therapeutic research, 57(8), 1996, pp. 579-588
Citations number
9
Categorie Soggetti
Pharmacology & Pharmacy","Medicine, Research & Experimental
Insulin sampled at various levels within several insulin preparation v
ials underwent high-performance liquid chromatography and fluorescence
spectrophotometry to determine insulin content, Insulin content did n
ot vary with Actrapid Human Insulin(R), Monotard Human Insulin(R), and
Novolin N100(R), regardless of the site of sampling, However, the ins
ulin content of Novolin U40(R) tended to decrease as levels in the via
l decreased, Novolin U40 was also administered subcutaneously to rabbi
ts to determine its effect on blood glucose, Blood glucose levels and
the frequency of convulsions due to hypoglycemia varied depending on t
he site in the insulin preparation vial, Our findings suggest that var
iation in insulin content at different sites of the vial may account f
or unstable control of blood glucose levels in diabetic patients recei
ving Novolin U40.