Comminuted fractures of the proximal ulna, particularly in combination
with dislocation of the radial head, represent complex injuries which
threaten both elbow and forearm motion. Thirty-seven complex proximal
ulna fractures were treated with a dorsally applied, limited-contact
titanium plate, contoured to lit the anatomy of the olecranon and prox
imal ulna. Twenty-four patients had Monteggia fracture/dislocations, a
nd 13 had isolated but complex fractures of the proximal ulna. After a
n average follow tip of 24 months, good or excellent functional result
s were achieved in 27 patients. Copyright (C) 1996 Elsevier Science Lt
d.