PERFORMANCE OF A COMBINED ANAEROBIC REACTOR FOR MUNICIPAL WASTE-WATERTREATMENT AT AMBIENT-TEMPERATURE

Authors
Citation
H. Yu et Gk. Anderson, PERFORMANCE OF A COMBINED ANAEROBIC REACTOR FOR MUNICIPAL WASTE-WATERTREATMENT AT AMBIENT-TEMPERATURE, Resources, conservation and recycling, 17(4), 1996, pp. 259-271
Citations number
14
Categorie Soggetti
Environmental Sciences","Engineering, Environmental
ISSN journal
09213449
Volume
17
Issue
4
Year of publication
1996
Pages
259 - 271
Database
ISI
SICI code
0921-3449(1996)17:4<259:POACAR>2.0.ZU;2-3
Abstract
A bench-scale experimental study was carried out to investigate the ov erall performance of a combined anaerobic reactor for treating pre-set tled municipal wastewater at ambient temperature (18-28 degrees C) in terms of substrate removal efficiencies, biogas, methane production, v olatile fatty acid (VFA) profiles and effluent suspended solids (SS) c oncentration, etc. The tested reactor was a modified anaerobic baffled reactor (ABR). The second and third compartments were partly packed w ith supporting media. The experimental results were similar to, or com pared favourably with, other anaerobic reactor systems for municipal w astewater treatment at ambient temperature and proved the technical fe asibility of this compartmentalised reactor. Considering its simple st ructure and operation, it could be considered a potential reactor syst em for treating municipal and domestic wastewaters in tropical and sub -tropical areas of developing countries.