A ROSETTE SYSTEM FOR THE COLLECTION OF TRACE-METAL CLEAN SEAWATER

Citation
Cn. Hunter et al., A ROSETTE SYSTEM FOR THE COLLECTION OF TRACE-METAL CLEAN SEAWATER, Limnology and oceanography, 41(6), 1996, pp. 1367-1372
Citations number
25
Categorie Soggetti
Oceanografhy,Limnology
Journal title
ISSN journal
00243590
Volume
41
Issue
6
Year of publication
1996
Pages
1367 - 1372
Database
ISI
SICI code
0024-3590(1996)41:6<1367:ARSFTC>2.0.ZU;2-T
Abstract
We designed a large-volume rosette sampler for collecting seawater wit h minimal trace metal contamination. The system uses eight modified 30 -liter Go-Fro bottles secured to a Nylon II-coated stainless steel fra me. The instrument is deployed with a dedicated winch with polyurethan e-coated, three-conductor Kevlar hydroline. A prototype was used as pa rt of the U.S. JGOFS Equatorial Pacific sampling program during spring and fall 1992. A redesigned model was used during the 1993 IronEx exp eriments and is currently being deployed in the Arabian Sea. The resul ts of trace metal analyses collected on these cruises indicate that sa mples recovered are comparable to current single Go-Fro casts.