Ac. Hoffmann et al., THE EFFECT OF THE DUST COLLECTION SYSTEM ON THE FLOWPATTERN AND SEPARATION EFFICIENCY OF A GAS CYCLONE, Canadian journal of chemical engineering, 74(4), 1996, pp. 464-470
The influence of the presence of a hopper section, consisting of a dus
t hopper and swirl attenuator, under gas-solid cyclones has been inves
tigated by numerical simulation. Inclusion of this configuration in th
e simulations was found to have a significant influence on both flowpa
ttern and separation efficiency. Moreover, predicted axial gas velocit
y profiles agreed better with independent experimental measurements. T
he cyclone separation was predicted to be better with the hopper secti
on included than without, a physical reason is proposed. Comparison of
simulated grade-efficiency curves with experimental data indicates im
proved agreement, in some cases substantially so.